Difference between revisions of "The DICOM Service Configurator"

From MircWiki
Jump to navigation Jump to search
Line 3: Line 3:
 
==Top-level Trial Parameters==
 
==Top-level Trial Parameters==
 
[[Image:DicomConfig1.JPG|frame|]]
 
[[Image:DicomConfig1.JPG|frame|]]
 +
At the top of the DICOM Service Configurator window is a small table containing parameters that are apply to all the components of the DICOM Service.
 +
 +
If you want the DICOM Service to start automatically whenever the MIRC site is started, set the <b>Autostart</b> value to <b>yes</b>.
 +
 +
If you do not want all transmissions to be logged in the <b>trial/logs</b> directory under the root of the storage service, set the <b>Log</b> value to <b>no</b>. Some trials require logs of all transmissions, so carefully consider this change.
 +
 +
If you want duplicate images (images with the same SOP Instance UIDs) to update previous versions, making the last image received the only one stored and referenced in the MIRCdocument, set the <b>Allow overwrite</b> value to <b>yes</b>. This is the way most trials are operated. If you want all images, even ones with duplicate SOP Instance UIDs, to be saved and referenced, set the value to <b>no</b>.
  
 
==Central Remapper Parameters==
 
==Central Remapper Parameters==

Revision as of 19:01, 30 August 2006

The DICOM Service Configurator provides a user interface for setting the parameters in the trial.xml file. It also provides access to the DICOM Anonymizer Configurator. The DICOM Service Configurator is accessed by clicking the Update Configuration button in the DICOM Service column on the storage service's admin page.

1 Top-level Trial Parameters

Error creating thumbnail: Unable to save thumbnail to destination

At the top of the DICOM Service Configurator window is a small table containing parameters that are apply to all the components of the DICOM Service.

If you want the DICOM Service to start automatically whenever the MIRC site is started, set the Autostart value to yes.

If you do not want all transmissions to be logged in the trial/logs directory under the root of the storage service, set the Log value to no. Some trials require logs of all transmissions, so carefully consider this change.

If you want duplicate images (images with the same SOP Instance UIDs) to update previous versions, making the last image received the only one stored and referenced in the MIRCdocument, set the Allow overwrite value to yes. This is the way most trials are operated. If you want all images, even ones with duplicate SOP Instance UIDs, to be saved and referenced, set the value to no.

2 Central Remapper Parameters

Error creating thumbnail: Unable to save thumbnail to destination

3 DICOM Import Service Parameters

Error creating thumbnail: Unable to save thumbnail to destination

4 Dicom Export Service Parameters

Error creating thumbnail: Unable to save thumbnail to destination

5 HTTP Import Service Parameters

Error creating thumbnail: Unable to save thumbnail to destination

6 HTTP Export Service Parameters

Error creating thumbnail: Unable to save thumbnail to destination

7 Database Export Service Parameters